Ferralium 255

The reference chemistry table for Ferralium 255 lists Carbon (C): 0.025% Max; Manganese (Mn): 0.80 – 1.20%; Silicon (Si): 0.70% Max; Phosphorus (P): 0.025% Max. Confirm exact limits and analysis tolerances against the governing standard and product form.

The mechanical-property table for Ferralium 255 lists Tensile Strength: 790 Minimum MPa; Yield Strength: 586 Minimum MPa; Elongation: 25 Minimum %; Hardness: 220 – 270 HB. These are reference entries; supplied condition, dimensions, test method and governing specification control the requirements, and the figures are not design allowables.

Werkstoff / EN cross-reference for Ferralium 255: 1.4507. This comparison does not guarantee interchangeability; confirm chemistry, product form and condition against the governing specification.

View Technical Information →
TECHNICAL INFORMATION

Material Identification

Standard identification and material designation information for Ferralium 255.

Material Ferralium 255
UNS Number S32550
Werkstoff Number 1.4507
Material Type Super Duplex Stainless Steel
MATERIAL PROPERTIES

Chemical Composition

The reference chemistry table lists Carbon (C): 0.025% Max; Manganese (Mn): 0.80 – 1.20%; Silicon (Si): 0.70% Max; Phosphorus (P): 0.025% Max. Confirm the governing standard, product analysis tolerances and product form before ordering.

Element Symbol Composition
Carbon C 0.025% Max
Manganese Mn 0.80 – 1.20%
Silicon Si 0.70% Max
Phosphorus P 0.025% Max
Sulfur S 0.005% Max
Chromium Cr 24.50 – 26.50%
Nickel Ni 5.50 – 6.50%
Molybdenum Mo 3.10 – 3.80%
Copper Cu 1.50 – 2.00%
Nitrogen N 0.20 – 0.25%
Iron Fe Balance
PERFORMANCE DATA

Mechanical Properties

The table reports Tensile Strength: 790 Minimum MPa; Yield Strength: 586 Minimum MPa; Elongation: 25 Minimum %; Hardness: 220 – 270 HB as reference data for Ferralium 255. Actual requirements depend on condition, dimensions, test method and specification; these values are not design allowables.

Property Value Unit
Tensile Strength 790 Minimum MPa
Yield Strength 586 Minimum MPa
Elongation 25 Minimum %
Hardness 220 – 270 HB
MATERIAL DATA

Physical Properties

Density Approx. 7.81 g/cm³
Elastic Modulus Approx. 199 GPa
Thermal Conductivity Approx. 14.2 W/m·K
Specific Heat Approx. 475 J/kg·K
Thermal Expansion Approx. 11.1 × 10⁻⁶ /°C
WHY SELECT THIS MATERIAL

Material Characteristics

Ferralium 255 combines high mechanical strength, excellent corrosion resistance and good toughness for severe industrial and marine service conditions.

01

Excellent Corrosion Resistance

Provides excellent resistance to aggressive chemical and chloride- containing environments.

02

High Mechanical Strength

Offers significantly higher strength than many conventional stainless steels.

03

Pitting & Crevice Resistance

Designed to provide excellent resistance to localized corrosion in severe service.

04

Good Toughness

Maintains good ductility and impact strength in demanding applications.

Ferralium 255 Bolting Products

INDUSTRIAL USE

Typical Applications

Ferralium 255 is selected for applications requiring high strength and reliable corrosion resistance in severe environments.

01

Oil & Gas

Offshore and high-pressure equipment exposed to corrosive service environments.

02

Marine & Offshore

Components exposed to seawater and chloride-containing environments.

03

Chemical Processing

Equipment used in aggressive chemical processing environments.

04

Desalination

Corrosion-resistant components for demanding seawater processing systems.

ENGINEERING GUIDE

Engineering Considerations

Corrosion Environment

Consider chloride concentration, chemical composition and operating temperature when selecting Ferralium 255.

Fabrication

Appropriate fabrication and welding procedures should be used to maintain the required duplex microstructure and corrosion resistance.

Mechanical Requirements

Ferralium 255 is particularly suitable where high strength and corrosion resistance are required together.

COMMON QUESTIONS

Frequently Asked Questions

What is the Werkstoff number for Ferralium 255?

The commonly listed Werkstoff / EN cross-reference for Ferralium 255 is 1.4507. Treat this as a grade comparison, not a guarantee of interchangeability. Verify chemistry, product form, condition and governing specification against the supplier certificate before substitution.

Where is Ferralium 255 used?

It is commonly used in offshore, marine, oil and gas, chemical processing and desalination applications.

Is Ferralium 255 corrosion resistant?

Yes. Ferralium 255 provides excellent resistance to pitting, crevice corrosion and demanding chloride-containing environments.

ENGINEERING SUPPORT

Need Help Selecting the Right Material?

Our engineering team can help you select suitable materials based on operating temperature, pressure and service conditions.

Contact Engineering